PRTG Manual: PerfCounter IIS Application Pool Sensor
<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: PerfCounter IIS Application Pool Sensor
The PerfCounter IIS Application Pool sensor monitors a Microsoft Internet Information Services (IIS) application pool via Windows performance counters.
PerfCounter IIS Application Pool Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
Dutch: PerfCounter IIS Application Pool
French: IIS Pool d'applications via Windows PerfCounter
German: Leistungsindikator IIS-Anwendungspool
Japanese: パフォーマンスカウンター IIS アプリケーションプール
Portuguese: Pool de aplicativos IIS (PerfCounter)
Russian: Пул приложений IIS (PerfCounter)
Simplified Chinese: 性能计数器 IIS 应用程序池
Spanish: Grupo de aplicaciones IIS (PerfCounter)
Remarks
This sensor requiresat least Windows Server 2008 R2 on the probe system.
This sensor requires Microsoft Internet Information Services (IIS) as of version 7.5 on the target system.
This sensor requires that the Remote Registry Windows service runs on the target system.
This sensor requires credentials for Windows systems in the settings of the parent device.
This sensor supports IPv6.
This sensor has a low performance impact.
This sensor uses lookups to determine the status values of one or more channels.
You cannot add this sensor to the hosted probe of a PRTG Hosted Monitor instance. If you want to use this sensor, add it to a remote probe device.
Detailed Requirements
Requirement
Description
Windows version
To work with Windows performance counters, this sensor requires that at least Windows Server 2008 R2 is installed on the probe system (on every cluster node, if on a cluster probe).
IIS version 7.5
To monitor IIS application pools, this sensor needs at least IIS version 7.5 to be installed on the target system.
Remote Registry Windows service
To work with Windows performance counters,this sensor requires that the Remote Registry Windows service runs on the target system. If this service does not run, a connection via performance counters is not possible.
To enable the service, log in to the respective system and open the services manager (for example, via services.msc). In the list, find the respective service and set its Start Type to Automatic.
Windows credentials
This sensor requires credentials for Windows systems in the settings of the parent device. We recommend that you use Windows domain credentials.
If you use local credentials, make sure that the same Windows user accounts (with the same user name and password) exist on both the probe system and the target system. Otherwise, a connection via performance counters is not possible. However, WMI connections might still work.
The user account has to be a member of the Performance Monitor Users user group on the target system.
If the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?
This setting is for your information only. You cannot change it.
Tags
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
pciisapppool
performancecounter
Priority
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
IIS Application Pool Specific
IIS Application Pool Specific
Setting
Description
Application Pools
The name of the application pool that this sensor monitors.
Sensor Display
Sensor Display
Setting
Description
Primary Channel
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
Graph Type
Define how different channels are shown for this sensor:
Show channels independently (default): Show a graph for each channel.
Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
Stack Unit
This setting is only visible if you select Stack channels on top of each other above.
Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window (default).
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
Channel Unit Configuration
Which channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.
Channel Unit Configuration
For more information, see section Root Group Settings, section Channel Unit Configuration.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel
Description
Application Pool State
The overall application pool status
Up status: Running, Unavailable for Total
Warning status: Initialized, Shutdown Pending
Down status: Delete Pending, Stopped, Stopping, Unavailable, Uninitialized
This channel is the primary channel by default.
Downtime
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down state
Worker Process Failures
The number of failures in worker processes
Worker Process Ping Failures
The number of failures in worker process pings
Worker Process Shutdown Failures
The number of failures in worker process shutdowns